Search: GERSTEL MPS Prepstation, Headspace
Results
- Rapid Automated Analysis of Benzene in Soft Drinks
In March 2006 the Food Standards Agency published the results of a survey which was designed to investigate the levels of benzene in 150 soft drinks in the UK. Although benzene was not detectable in the majo ...
Resource - Susan Gilbert - 15th Apr 2011 - 0 comments
- A Summary of the Anatune Environmental VOC System
Headspace sampling for Environmental VOCs is a proven technique for rapid quantitation of soil and water samples and has rapidly become the method of choice for many Environmental testing companies. Anatune ...
Resource - Susan Gilbert - 15th Apr 2011 - 0 comments
- Automated Spiking of Internal Standards and Surrogates to build Calibration Curves using the GERSTEL MPS PrepStation
This note follows on from Anatune application note AS53 and extends that work by automating the addition of internal standards and surrogates to calibration standards and samples. This enables accurate and re ...
Resource - admin - 9th Sep 2010 - 0 comments
- Automated On-Line Construction of Calibration Curves using the GERSTEL MPS PrepStation
This note follows on from Anatune application notes AS30, AS45 and AS55, and extends that work by automating the addition of solutions of standards, internal standards and surrogates to calibration samples an ...
Resource - admin - 9th Sep 2010 - 0 comments
- On-Line Construction of Calibration Curves for the Analysis of Selected Red-List Solvents & THMs in water using the GERSTEL MPS Prepstation
This note follows on from Anatune application notes AS30, AS45, AS53, AS55, AS56 and AS58, and extends that work by automating the addition of solutions of standards, internal standards and surrogates to cali ...
Resource - admin - 9th Sep 2010 - 0 comments
- Automated Addition of Internal Standards, Surrogates and Water Prior to Headspace Analysis of VOCs in Soil
Previous Anatune application notes have described the automated addition of internal standards and surrogates to water samples prior to their headspace sampling for VOC analysis. This note extends that work ...
Resource - admin - 9th Sep 2010 - 0 comments
- Improvements in Productivity for GERSTEL PREP Sequences
The spiking of calibration curves, AQC and calibration drift standards and the addition of internal standards to samples can now be performed in a more time-efficient manner. Previous Anatune application not ...
Resource - admin - 9th Sep 2010 - 0 comments
- Further Increases in Capacity for the Automated Spiking of Internal Standards and Surrogates using the GERSTEL MPS XL PrepStation
Automating the addition of internal standards and surrogates enables accurate and reproducible volumes to be added to each vial in a just-in-time manner prior to injecting the sample. This application has pr ...
Resource - admin - 9th Sep 2010 - 0 comments
- Automated Spiking of Internal Standards and Surrogates using the GERSTEL MPS PrepStation
Automating the addition of internal standards and surrogates enables accurate and reproducible volumes to be added to each vial in a just-in-time manner prior to injecting the sample. By proving this applica ...
Resource - admin - 9th Sep 2010 - 0 comments