- The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques
The Focus is a multifunctional instrument and can be used for the automated preparation and injection of samples using many techniques, for example SPME, headspace, liquid-liquid extraction, thermal desorptio ...
Resource - Susan Gilbert - 18th Apr 2011 - 0 comments
- Improvements in Productivity Using the Fast GC Bundle
This application note details improvements where the analysis desires a single ramp program, for multi-ramp0 applications please refer to application note AS72. Improvements were achieved by using the innova ...
Resource - Susan Gilbert - 15th Apr 2011 - 0 comments
- Using the GERSTEL Multi Purpose Sampler (MPS) Purge Tool as a Simple Evaporator
This short technical note describes the use of the purge tool as a simple evaporation device when combined with a Multi Purpose Sampler. The purge tool is an add on accessory for the GERSTEL MPS 2 Multi Purp ...
Resource - Susan Gilbert - 15th Apr 2011 - 0 comments
- Using the GERSTEL Multi Purpose Sampler (MPS) as a Large Volume Fraction Collector
This short technical note describes the use of a GERSTEL Multi Purpose Sampler (MPS) as a fraction collector. A fraction collector is a device that allows regular or specified samples to be taken from a colu ...
Resource - Susan Gilbert - 15th Apr 2011 - 0 comments
- Automated Solid Phase Microextraction using the GERSTEL MPS Prepstation and MAESTRO Software
Solid phase microextraction (SPME) is a powerful technique for the analysis of trace components in a wide variety of matrices. The types of compounds which can be analyzed by this technique ranges from non-p ...
Resource - Susan Gilbert - 14th Apr 2011 - 0 comments
- Determination of propargyl alcohol in aqueous samples by SPME and GC/MS analysis
Propargyl alcohol, a waste product of the pharmaceutical industry, is very toxic and because of its polarity very difficult to determine in the aquatic environment. In this study, Solid Phase MicroExtraction ...
Resource - Susan Gilbert - 14th Apr 2011 - 0 comments
- Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control
In addition to providing unattended operation as an autosampler for a chromatographic instrument, the use of the MultiPurpose Sampler (MPS) robot in combination with the MAESTRO software enables full automati ...
Resource - Susan Gilbert - 14th Apr 2011 - 0 comments
- Stir Bar Sorptive Extraction: Capacity and Competition Effects
The determination of volatile and semivolatile analytes in aqueous solutions using stir bar sorptive extraction (SBSE) as the extraction step is gaining acceptance in a wide variety of application areas inclu ...
Resource - Susan Gilbert - 25th Jan 2011 - 0 comments
- Elimination of Polar Matrix Components Prior to GC Analysis using Stir Bar Sorptive Extraction (SBSE)
Analysis of samples containing polar matrix components such as water, glycols, sugars or surfactants by gas chromatography has usually required extensive cleanup such as liquid/liquid extraction, solid phase ...
Resource - Susan Gilbert - 25th Jan 2011 - 0 comments
- Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase
The analysis of volatile and semivolatile compounds in aqueous solutions using stir bar sorptive extraction (SBSE) as the extraction step is gaining acceptance in a wide variety of application areas including ...