Search for and download brochures, application notes, presentations and posters.
Read our Blog!
Search here for recent application notes from Anatune and our partners.
We organise our own events and attend many others.

We love to talk with our customers face-to-face so, if you are attending an event, let us know and we can arrange to meet.
Lunch & Learn seminars are provided free by Anatune and consist of one-hour sessions, conducted by experienced analytical chemists, covering topics that are relevant to the work you do.
Download copies of recent presentations given by the Anatune team.
Here you can download copies of recent posters presented by the Anatune team and our partners.
Who we are, what we do and what we believe is important.
We recognise that data quality, analytical flexibility and effective support should be our primary concern and Anatune is dedicated to delivering these benefits to analysts in the UK and Ireland.
Our first priority is to maintain a great team spirit and we only employ people with great attitudes.

We believe in continual learning and personal development. We train our staff well.

Find out more about them here.
Our role is to bring the World's best analytical technologies to laboratories in the UK and Ireland.

We do this in partnership with some great companies.
We do our best work and achieve the very best outcomes when collaborating with our customers.
We have built strong, long-term relationships with customers resulting in repeat business and an unbeatable reputation for reliability and trust.

Here's what they say about us...
While it’s certainly not our primary motivation, peer recognition is important to us. See our latest and greatest achievements here.

Showing blog posts from Matrix: Water



Methanolic Extraction of Soils by Automated Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)

Posted on January 19th, 2021


Method Validation of Volatile Organic Compounds (VOCs) in Water Using the Anatune Robotic VOC Analyser

Posted on January 12th, 2021


Automated Weighing Option: Proving the Accuracy of Automated Sample Prep

Posted on May 20th, 2020


Speciation of Dichloromethane and Chloroform Using Negative Ion SIFT-MS

Posted on January 30th, 2020


Fully Automated System for Preparing and Analysing Samples for NDMA in Potable Water Using GC-QQQ

Posted on November 12th, 2019


Dispersive Liquid-Liquid MicroExtraction Compendium

Posted on September 25th, 2019


Automated Solutions Using Small Scale SPE to Solve Challenging Applications

Posted on September 11th, 2019


Determination of Trace (pg/L) Levels of Cypermethrin in Water Using Stir Bar Sorptive Extraction

Posted on September 11th, 2019


Rapid Analysis of BTEX in Water Using Automated SIFT-MS

Posted on September 11th, 2019


Rapid Analysis of Organochlorine Compounds in Water Using Automated SIFT-MS

Posted on September 11th, 2019


Method Validation of the Analysis of Organochlorine Pesticides and Polychlorinated Biphenyls Using DiLLME and GC-MS/MS

Posted on September 3rd, 2019


Automated Method for the Extraction and Derivatisation of Alkylphenols, Ethoxylates and Bisphenol A in Water

Posted on July 17th, 2019


Initial Work for Automation of a BSTFA Derivatisation for Phenolic Compounds in Water

Posted on May 22nd, 2019


Initial Development Work for the Automated Derivatisation of Glyphosate and Aminomethylphosphonic Acid in Water Followed by LC-QQQ Analysis

Posted on March 13th, 2019


Comparison of the Agilent 5977B MSD with High Efficiency Source and 7250 Q-TOF for Analysis Using Dispersive Liquid-Liquid MicroExtraction of Semi Volatile Organic Compounds

Posted on February 6th, 2019


Optimisation of a Large Volume Injection (LVI) Method for Organic Contaminants in Water Using Design of Experiments (DoE)

Posted on October 24th, 2018


Automated Liquid-Liquid Extraction of Epichlorohydrin Using GC-MS

Posted on October 10th, 2018


A Fully Automated Approach to the Analysis of NDMA in Water

Posted on August 2nd, 2018


Investigation of the Agilent 5977B with High Efficiency Source (HES) to Enable Electron Impact (EI) Analysis of Phenolic Compounds in Water

Posted on June 20th, 2018


Automated Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)

Posted on June 6th, 2018


Initial GC/Q-TOF Work for Trace Analysis of Organochlorine Pesticides Using NCI

Posted on April 19th, 2018


Automated Online Desorption and Analysis of DNPH Derivatives of Formaldehyde, Acetaldehyde and Related Carbonyl Compounds Using a New Robotic Autosampler

Posted on March 21st, 2018


Large Volume Injection of Flame Retardants Using the CIS-4 Inlet

Posted on March 15th, 2018


Offline Automated Extraction of Non-Polar Pesticides in Water with Analysis by GC-MS

Posted on February 1st, 2018


PrepAhead: How to Master Your Time with GERSTEL Maestro Software

Posted on January 24th, 2018


Initial Work on Automating Dispersive Liquid-Liquid MicroExtraction (DiLLME) for EPA 8270

Posted on December 15th, 2017


NS30 and Stability Tests Using the New Anatune VOC Analyser

Posted on November 23rd, 2017


Fully Automated Liquid-Liquid Extraction on Low Level Trichloranisole Using GERSTEL Robotic

Posted on November 15th, 2017


The MultiFlex GC/Q-TOF as a Tool for the Investigation of Taste and Odour in Drinking Water

Posted on November 9th, 2017


Determination of Acetaldehyde in Water from Plastic Bottles Using Hot Injection Trapping (HIT) Technique on GC-MS

Posted on October 19th, 2017


Automated Liquid-Liquid Extraction of Geosmin in Water by GC-MS/MS

Posted on October 18th, 2017


Fully Automated Liquid-Liquid Extraction Method Using a GERSTEL Dual Head Robotic with Robotic Pro of Organochlorine Pesticides and Polychlorinated Biphenyls in Water

Posted on September 27th, 2017


A Fully Automated Liquid-Liquid Extraction for 2-Methylisoborneol and Geosmin in Water

Posted on August 31st, 2017


Use of SPE and Twister (SBSE) to Enrich Heptachlor and Heptachlor Epoxide From Water with a GC/Q-TOF in NCI

Posted on June 2nd, 2017


Initial Work for Automation of Polycyclic Aromatic Hydrocarbons in Water

Posted on March 10th, 2017


On-line Monitor for Metaldehyde in Surface and Ground Water

Posted on February 15th, 2017


Initial Work for Automation of Organochlorine Pesticides and Polychlorinated Biphenyls in Water

Posted on February 10th, 2017


Offline Sample Preparation of Acid Herbicide Samples for LC-MS Analysis Using a Dual Head MultiPurpose Sampler

Posted on April 6th, 2016


Optimisation and Validation of an ITSP Method for the Determination of Taste and Odour Compounds in Water

Posted on February 26th, 2016


Fully Automated Solution for the Extraction of Non-Polar Pesticides by GC

Posted on November 25th, 2015


Initial Work for the Determination of Taste, Odour and Phenolic Compounds in Water Using ITSP on the New Agilent GC-QQQ 7010

Posted on November 4th, 2015


A Fully Automated and Quantitative Method for Metaldehyde in Water Using GC-QQQ

Posted on June 10th, 2015


Trace Level Enrichment of Malodour Analytes in Water Using Twister Technology

Posted on June 10th, 2015


Analysis of Formaldehyde and Acetaldehyde Using Automated DNPH Derivatisation

Posted on June 10th, 2015


Determination of VOCs in Water Using the New Anatune VOC Analyser

Posted on May 20th, 2015

Static headspace extraction with Gas Chromatography-Mass Spectrometry (HS-GC/MS) is an established technique for the determination of volatile organic compounds (VOCs)…


What Compounds Can Be Analysed with SIFT-MS?

Posted on March 17th, 2015

A guide to compounds that can be analysed using SIFT-MS.


The On-Line Measurement of VOCs in Flowing Water

Posted on December 1st, 2014


Trace Analysis of Polycyclic Aromatic Hydrocarbons (PAHs) in Water Using Twister SBSE Technology

Posted on July 30th, 2014


Go back to Blog Homepage