Search for and download brochures, application notes, presentations and posters.
Read our Blog!
Search here for recent application notes from Anatune and our partners.
We organise our own events and attend many others.

We love to talk with our customers face-to-face so, if you are attending an event, let us know and we can arrange to meet.
Lunch & Learn seminars are provided free by Anatune and consist of one-hour sessions, conducted by experienced analytical chemists, covering topics that are relevant to the work you do.
Download copies of recent presentations given by the Anatune team.
Here you can download copies of recent posters presented by the Anatune team and our partners.
Who we are, what we do and what we believe is important.
We recognise that data quality, analytical flexibility and effective support should be our primary concern and Anatune is dedicated to delivering these benefits to analysts in the UK and Ireland.
Our first priority is to maintain a great team spirit and we only employ people with great attitudes.

We believe in continual learning and personal development. We train our staff well.

Find out more about them here.
Our role is to bring the World's best analytical technologies to laboratories in the UK and Ireland.

We do this in partnership with some great companies.
We do our best work and achieve the very best outcomes when collaborating with our customers.
We have built strong, long-term relationships with customers resulting in repeat business and an unbeatable reputation for reliability and trust.

Here's what they say about us...
While it’s certainly not our primary motivation, peer recognition is important to us. See our latest and greatest achievements here.

The Power of Low Energy EI Ionisation in GC/Q-TOF MS

Application Note

In standard GC-MS analysis Electron impact (EI) ionisation is performed at 70eV, producing established fragmentation patterns that are used in many commercial libraries. In some cases, the molecular ion is weak, or absent altogether, making unequivocal identification challenging. Using a specially designed source the Agilent 7250 QTOF is cable of performing a ‘low energy’ EI ionisation, providing the opportunity to increase the relative intensity of the molecular ion and help with structural elucidation. This application note describes the optimisation of Low Energy EV using Design of Experiments and subsequent analysis of Farnesol isomers for comparison with standard 70Ev EI ionisation. Results demonstrated this approach for Characterisation of Isomers and Identification of unknowns in a customer sample.

Application Note Downloads
AS202

The power of low energy EI ionisation in GC/Q-TOF MS

 